navien 240a recirculation settings

Having just run my own recirc lines and installing an NPE240A I can tell you that you dont want intelligent preheat. 800-556-7556 or see HarryEklof.comFull Naivien information including dealer and Rep locators is available at www.navieninc.com Your observation about the Enable/Disable selection saved the day! Apple iOS Google Android NPE-240A Downloads Click here to see downloads for other products. A tankless water heater, whether it comes from Navien or other brands, will provide you a reliable service for up to 20 years if you maintain it according to the manual. Tech support is clueless. https://www.navieninc.com/products/npe-240a/downloads#search, NaviLink Timer Schedule not being followed, Navien 240A (Controlling the Circulation Pump). I am looking at options for my recirculation too. Press the M (menu) button and head over to 1.Recirculation Setting > 2. Efficient, durable and high-performance products for any commercial application. I have even had to swap out control and front panel boards to get the function to work, but they broke that with an app update. What follows is a journey into a ridiculous realm. As for parameters 12 & 14, I would at least try to play with them to see if it helps. Put the PCB box back in its original place and secure it using. Sign In Upload. Internal will keep open the same valves but also use the internal pump as set, and not rely on any external pump. Dave, if you could enlighten me (other users) on what you had to do to get scheduling to work that would be great. 6. Navien 240a Tankless Water Heater from hybridwaterheater.blogspot.com. Read the user's Navien nr-240a manual to get information on how to flush the heat exchanger and reset the remote for Navien tankless water heater. Also, NaviLink Lite does not require external power. We do not have a hot button. For example, it will boost up the energy consumption because the unit operates to maintain the water temperature within the circulation loop. The app is not the most intuitive. High-efficiency condensing and non-condensing tankless water heaters offer endless hot water and reduce gas usage. It's unfortunate he's not around to explain all this to you. So when you request hot water, its going to start the pumps to make sure that water stays heated as it passes through. Part No. How often should you flush a Navien tankless water heater? Nearly Instantaneous hot water can be achieved with a Navien tankless water heaters with a proper recirculation system but is dependant on the homes piping system.Please contact Harry Eklof \u0026 Associates for more information or to set up a training class for your company. I've learned some things myself. 1. Can you Ask an Expert Home Improvement Questions HVAC Questions Michael Ferryman 1,933 Satisfied Customers Operating Engineer at NRG Energy Michael Ferryman is online now Related HVAC Questions Replacing one NPE for two 90 gallon tanks ( one dead and one likely to die) was a cost savings even though the NPE and recirc is expensive. Specifically, you can find a number of dip switches on these two locations. Thanks for the comments folks. * The cold-water sandwich effect is the undesired introduction of cold water into the hot water supply line on occasions of frequent on/off operations. Understanding Navien Recirculating Water Heater - Heating Help: The Wall (Measure Guideline : Transitioning to a Tankless Water heater, DOE, Sept.2012). 20. Also, you can use the Navien Intelligent Preheating feature. Finally I got them to call the Navien support line to set them straight. It will reduce the energy consumption and deliver you the best heating efficiency. Navien NPE240A- Navilink,Navilink App, Recirculation settings And Click here to see downloads for other products. Thats an interesting question and I am not sure of the answer. Error Code E047 I have a Navien NPE-240A tankless heater, . I just got off the phone with a "Senior" support specialist. The Intelligent preheating on Navien Water Heater is a self-learning process that you can enable by turning on the DIP switch on the front panel. It may not display this or other websites correctly. By accepting all cookies, you agree to our use of cookies to deliver and maintain our services and site, improve the quality of Reddit, personalize Reddit content and advertising, and measure the effectiveness of advertising. Eventually, I want to run a return line from the kitchen area back to the hot water heater and that should significantly reduce the delivery time, since all the faucets feed off the line that leads to the kitchen. I would make my back steps half of the known good/bad settings to speed up the search process. Maybe the new NPE is more efficient than the NR. I hate the app as it is just not user friendly. On-demand takes a bit longer to heat up, but oh well. Sorry just saw this. The update is not perfect, but seems to be much more user friendly interface. Set the front panel DIP switches at the far left (set of ten) to: 1ON; 2 OFF. I too have the NPE-240A, and this is what was explained to me. Then I searched and discovered your posting. I tried reconnecting using the AP button. Adjust the recirculation settings from the front panel. The control is recirculation only. PDF Navien npe-240a recirculation settings - Ziepniekkalns Navien 240A Dip Switch Settings [Explained] - lildutchuncle.com I, recently had a Navien NPE-240A unit installed. The Since the 210A has an internal pump, this confused me. It is assumed that when you connect a hot button that you only want it to recirculate when you hit the button, and it is assumed that when you connect a Navilink that you will set up a schedule and have it recirculate within those hours specified. The A2 is the upgrade that started shipping in March 2021. You are using an out of date browser. Water heater without tanks, also called instant water heaters heat water immediately upon request. "If you can't explain it simply, you don't understand it well enough". Internal vs External Recirculation - Navien 210A : r/Plumbing - reddit We have a Navien NPE-240A boiler and an electrical (unconnected) hot water tank that acts as a storage tank. NaviLink & NaviLink Lite make it easy to communicate with your Navien systems anywhere internet service is accessible. But you may need to flush the unit every six months if you live in a hard water area or operate the unit at a higher temperature setting. Navien Recirculation Settings have a lot of advantages. 8. PFFW-001, NaviCirc Kit: 30022965A. Below assumes the iDRAC has been configured and is available on the network in default config. It just will not connect. Press J to jump to the feed. I simply cannot believe the iPhone app won't allow both recirc schedule on a dedicated loop and ability to turn on/off recirc at other times. If the hot button is not engaged, or a schedule is not specified and enabled in the app then the water heater simply will not re-circulate. Then if that doesn't work, I would keep it at 1 minute, and then set 14 to 1 minute, and I would also try 14 at its max. Save my name, email, and website in this browser for the next time I comment. It is compliant with California Title 24. On the control board, the display does not turn on, there is no clicking from the ignitor, and no pump trys to run. I actually only use the app to view status and utilization these days. the 2 mounting screws. We might be able to do something about it. The NaviLink system attaches easily to any new or existing* Navien tankless water heater, combiboiler and boiler. Error Code E046 There is something wrong with limit control. Colector ReadyLink Hoja De Especificaciones Espanol (USA & Can NPE Guia De Conversion De Gas (USA & Canada), NPE Guia De Instalacion Rapida Espanol (USA & Canada), Navien-NPE-Series-CSI 3-Part Formatted Specifications, Ready-Link Manifold 2BB Submittal Package, Ready-Link Manifold 2SS Submittal Package, Ready-Link Manifold 3SS Submittal Package, Ready-Link Manifold 4BB Submittal Package, Ready-Link Manifold 4SS Submittal Package. Designed for retrofit and new construction, the Navien H2Air Kit includes an add-on controller to integrate space heating and DHW between any NPE-A2 series tankless water heater and a hydronic air handler. We have a Navien NR-240A installed in new construction in 2012. * Existing installations may require the purchase of a new main PCB and front control panel. Since my VPN endpoints were not providing me w/ an updated client and w/ no access to Cisco Anyconnect downloads, my only option was to try openconnect. Navien NP-240A Manuals | ManualsLib Efficient and earth-friendly products designed for any size home. Correcting Navien Tankless Hot Water Heater Installation Resources | Partners Login | Become an NSS |Certifications |Parts List | Technical Support | Careers |Global Network |Warranty, All contents copyright Navien Inc. | About Navien |Contact Us | Terms of Use |Privacy Policy |CCPA |Notices, Ultra-high efficiency condensing tankless water heaters, High efficiency non-condensing tankless water heaters, You accept the use of cookies as described in our, PeakFlowE Installation, Operation and Maintenance Manual, Manual De Sistema Ventilacion Comun Espanol (USA & Canada). So what's going on here? The house is set up with recirculation, though I am not sure where in the house the "T" on the system is located. So, you must play with this setting and adjust it according to your water usage demand. I have had my professionally installed NPE-240A for about 8 months now and like it, but do experience longer times to get hot water to all the taps. dip one off, dip 2 on, everything else off (down is off). Navien Tankless Water Heater Standby Mode, Rinnai Tankless Water Heater Not Getting Hot Enough [Solved], Zoeller Sump Pump Wont Turn On [7 Easy Solutions]. I agree. To exit the view information mode, just press the back button on the front panel. These are your VPN endpoints that you would need to pass to openconnect. Part No. It does not specify what 'control' means. 60. Their are lots of ways your system may be piped. Thanks. NPE-A2 Series | Navien So I just got off with a "Senior" support specialist at Navien Customer support. Hi therejust curious since I was considering a Navien 240A. Called Navien to find out what/if the dip switch settings should be when using the controller and they will not give them to me as the homeowner. Could someone please confirm that I should indeed have well pump "ON"? Create an account to follow your favorite communities and start taking part in conversations. Right now I have it on recirculate all day long, which gives me instant hot water, but wastes a lot of energy. Navien NPE-240A Installation Manual online [23/74] 118598 Once you turn that DIP switch, the water heater software will monitor the flow demands over a 7 day cycle and recirculate the water from the following week based on water usage. Internal with external pump. Navien Npe 240A Recirculation Settings My water is well water so I am assuming this is correct. I pushed the little lever inside the unit down to use the external line. For the Navilink and recirculation to work: May 14 2022. Navien NR-180(A); NP-180(A); NR-210(A); NP-210(A); NR-240(A); NP-240(A) Condensing Water Heater, Navien NP-240A Service Manual (179 pages), High Limit Switch or Exhaust Limit Switch, Preparing the Water Heater for Inspection, Navien NP-240A Operation & Installation Manual (89 pages), Navien NP-240A Installation Manual (78 pages), Contaminated Make-Up Air will Damage the Unit, Navien NP-240A Owner's Operation Manual (45 pages), Pump Activation Setting Function When Hot Water Is Used, "A" Series Models Built-In Circulation Function, Basic Troubleshooting and Frequently Asked Questions, Navien NP-240A Installation Manual (68 pages), Navien NP-240A Quick Installation Manual (4 pages). Navien NPE-240A dip switch settings help please : r/Plumbing - reddit PFFW-001, NaviCirc Kit: 30022965A. Can anyone lend some guidance as to what the recommended dip switch setting should be? Let's check the dip switch settings too. Internal with internal pump. Gas. Note: You must set up the Time Settings in the Configuration menu to choose these options. Say with external pump being used function, if your recirculation line connects together outside of the heater like with an actual return line then set it external. Connect the water supply. They understand systems like this and can help you choose the right pump and control that only recirculates when you tell it to. Recirculation is basically just keeping the hot water in the plumbing hot so you get hot water faster. On 12/6/2022 I just installed a Navien 240 A and talked to tech support for Navien 3 times about the NaviLink not controlling the unit. How does Navien intelligent recirculation work? My NaviLink was working just fine for about2 months. Efficient and earth-friendly products designed for any size home. High-efficiency condensing and non-condensing tankless water heaters offer endless hot water and reduce gas usage. But would like to have the 'instant button' in the app that I could push in the evening, where it would recirculate the water for me on demand, and then five min later I can take a hot shower. You can find this valve inside the water heater. Thanks in advance for any advice. I tried purging the line - Answered by a verified Plumber . It may not run the entire time but it does run. Strong signal. Navien 30015307A Circulation Pump, NCB-E Models OEM PART $272.95 In Stock FREE SHIPPING Navien 30002583A High Limit Switch, OEM PART $18.85 In Stock FREE SHIPPING Navien HotButton Recirc Pump Control for NPE-A Series, PZZZ-00046 $115.45 In Stock FREE SHIPPING NAVIEN 30014189B NHB FLAME ROD ASSEMBLY, OEM Part $31.38 In Stock FREE SHIPPING Press the M (menu) button on the front panel and choose the 1. Navien NPE-240A Installation Manual Page: 27 - mans.io Research I've seen suggests this will save over 90% of the energy costs associated with 24 hour recirculation, which is essentially what you have. I have had the system for a number of months now and overall I really like it. Press either the Up or the Down button to choose the scheduled time. How To Set Recirculation Mode On Navien Water Heater? With Navien's Ready-Link cascading technology, when a unit gets up to 80% capacity the next unit will turn on to help meet requirements. Protect the water supply and water heating equipment with eco-friendly water treatment solutions. This saves energy and provides an endless supply of hot water for households. It looks like you're using an ad blocker. Lastly, press and hold down the OK button for 2 seconds to finalize the weekly schedule setting. NAVIEN NPE-180A SERVICE MANUAL Pdf Download | ManualsLib There is 4 options (6 technically, but the 5th and 6th dont apply). So to speak "standard" recirc pumps are too small to get it the water heater to fire.If it is existing and it has worked in the past, then there may be something wrong with the circulator.Dave H. We have a Navien NR-240A installed in new construction in 2012. If you don't have external recirc pump dip 1 should be on. 1. 60. Yes, I know. Disabling schedules simply disables "recirculation", the function that keeps hot water hot in the plumbing for 'instant hot water'. We are on well water and have a low flowing well. External with internal pump. Quote. In reading the comments there seems to be confusing information as to whether the schedule button should be set to ENABLE or DISABLE. Remove the plastic insulation from the solenoid valve wire. Learn more about our products for home owners. If you want the heater to provide the cross over where the hot return and cold combine then set it to internal. Thanks for the summary and the reply to my question as well as the others. I was reading the directions, and it wants me to set the Heater to External recirculation. Weekly: It lets a user choose commands for DHW Recirculation on a weekly basis. Adding a "Hot button" overrides schedulers (navilink or NR-20DU). I don't have any answers to your questions, but I am curious to know how you like the overall setup? Displays temperature and water flow rate. How to use the recirculation modes on a Navien Water Heater? Assuming you've created a Transport Node Profile and associated w/ the cluster. The issue is related to a Navien heater Model NPE 240A recirculation Legal Disclosure:Lildutchuncle.com provides and shares information on plumbing, heating & air quality, home improvement, and other DIY projects. Turns out, the recirculation mode has three performance advantages, including: Now, lets see how to adjust the recirculation mode in the next chapter so that you can enjoy the advantages I mentioned. Looking at the various videos before buying the Navilink router, they make it seem like the app would include a 'hot button' feature. After much frustration getting the app installed and setting a schedule, we are unsure whether the app is actually communicating with the unit according to the schedule. You must log in or register to reply here. The problem is that NSX-T doesn't see the new host and its link to the compute manager (vCenter) looks fine. Any other comments/recommendations for a Navien tankless newbie are welcome! PreReqs: RACADM ktpass Powershell 3.0 (2.0 probably works too, but I was using 3.0@ the time) Your root CA's cert This is so it AD Authentication can be setup Solution: It's not a complete solution, but hopefully it'll help you get started in your own endeavors. with a wire stripper befor e connecting it to the solenoid valve. They stated that the "Default" re-circulation schedule is every 30 minutes if it senses a 9 degree drop. Internal Recirculation and make the selection by pressing the Ok button. I also wanted to enable domain authentication in a somewhat secure manner. Condensing combi-boilers deliver high-efficiency endless hot water and space heating in one compact unit. The flow on demand ratio will continue until all32 units are generating hot water as needed. Troubleshooting Navien NPE-240A Internal Recirculation Pump They are: If you want to select or activate any of the two recirculation modes, you must do two things: You can enjoy several benefits if you activate the recirculation mode. Residential Recirc setup with Navien NPE A for faster hot water With the -A uinits (with the recirculation pump) does that pump have to run to supply on demand hot water? Recently updated to an NPE-240A. I thank you for this post! Also, it will get hot water to you quickly depending on the length and size of branch lines off the recirc loop. For a better experience, please enable JavaScript in your browser before proceeding. Yierd! How To Use Recirculation Mode On Navien Water Heater? If you can post a picture of your setup it would really help. If you'd like to support the site, please allow ads. I kept looking at the programming trying to figure out what was wrong. Navien 240A Recirculation Settings I'll have to look at the manual again, but the one I have does detail dip switch settings. Summary: I was looking to automate configuration of iDRAC's (Dell Remote Admin Console) synonymous w/ iLOM and many other acronyms. Similar to the Navien NR-210A, the NR-240A is a tankless water heater with a built-in circulation pump and buffer tank, except that this model delivers 11 gallons per minute at 45oF rise. Navien even sent me a new NaviLink wireless controller which I installed with the same results. In particular I'd like to change the temperature at which it begins to recirculate, or the frequency of it. Is there a link that I can find this parameter table at? Misc: Navien NPE-240A Navilink App missing scheduling function I suspect a process issue. MacOS: AnyConnect VPN client was unable to successfully verify the IP forwarding table modifications. Protect your water supply and your water heating equipment with eco-friendly water treatment solutions. Navien tankless water heater recirculation | 2016-04-01 | Plumbing and Workaround: Restart the cm-inventory service on each NSX-T mgmt/controller node using API or CLI. This is a complete guide on Navien Recirculation Settings. You are incorrect. For more information, please see our is this recirculation pump just recently installed? Enable=Enabled, and Disable=Disabled. I have been battling this unit for 2 years. The app will not connect to my wifi. DIP Switch 1 Off, 2 On. NPE-240A Brochures, Manuals & Documents | Navien Navien Recirculation Settings: Everything You Should Know Am I correct in assuming this means that the internal loop and buffer tank only heat up when there is there is demand for hot water (i.e.