Sometimes I need to backwash and rinse before the water seems to get going enough to actually circulate, then Im able to switch to filter and it works. Hi, I changed my Sta Rite motor, it was 10 years old and did not start anylonger, with a brand new one. My pump impeller does not budge. Normally though, it takes more like 15 minutes before the pump is cool enough to turn back on again, at which point you may hear a click, as the overload resets, just a second before the pump turns on again. The hot side goes into the timer's N0-3 and common into com-1. Hi Yolanda, also a great question first plug something else like a hair dryer or lamp into the outlet, to be sure its supplying 115V properly (or use a test meter). Could it be a bad cord? Hi Davy, my pump is on a timer and will occasionally fail to turn on in the morning. But you could look further at the wires on the back of the terminal board, following them to the capacitor and switches problem lies where the power dies! I never had this problem before. If it makes no noise at all, that is often a loose wire or no power. When I installed the filter and pump the water in the filter came gushing out of the filter and the top mount was raised up even though the clamps were tightly screwed in place. Students and professors will find thorough, current coverage of all business research topics presented with a balance of theory and practical A Answered on 5/26/2022 by InyoPools Product Specialist Craig C.. Hello J. LibriVox About. Also in reviewing the setup, the salt water panel box does not even turn on on low. By morning all the dead algae filters back into the pool and it take about 4 days to clear. My pool guy went directly to saying I need a new one. If the switch does not close after the blower starts the control will go into lockout with the blower running. You can remove the pump basket and reach back with your fingers to see if any debris can be felt in the eye of the impeller (pump Off, of course, lol). Nick, it could be the capacitor, I guess water got on the terminal board, to trip the breaker. Recently when power came on it hums and shuts down after 6 seconds. Additional causes for low water flow in your pump are debris build-up or dirty equipment. For over 2 months, lots of troubleshooting, actually RE-PIPED THE SECTION FROM POOL TO PUMP done by professionalpump still will not primedraws water, wont primeplayed with outflow and values, no primetook apart (my nemesis) Hayward Perflex DE filter, cleaned fingers, silicone on gaskets, put back (I have done this crappy job a hundred times so I am familiar with the process)no primefeel like draining the damn pool and junking the whole thing >:(. So my Hayward melted the whole left sided plastic shrouds. Shock the pool first and overfilter, before pulling pump. hayward blue essence troubleshootingautodrive microfiber towels. A spike below 100V or above 140V, could blow a capacitor. Sparking can also come directly from a short in the windings of the motor. Ive done the reset and it still showing 4300. The pump is working fine, however only the low speed is working. last year, I replaced the Sand & O ring on the filter, and I resealed the O ring on both the filter & Pump with O ring lube. Specialties: Cycling, Kickboxing, The Twelfth Edition of Business Research Methods reflects a thoughtful revision of a market standard. I will be replacing it tomorrow along with the electric socket. Hi Rodney, well the Green wire should be ground, so that eliminates one choice. Is there any other switch? Mine is doing same thing. When they fail, they often crack, bulge, leak or smell bad, but not always. It could have also overheated, when this happens, it will work again after cooling down. You are using an out of date browser. March 2023 Issue - Donovan's Bookshelf Fourth, could be a clog or obstruction AFTER the pump, in the filter valve, or in the filter itself. Shut off power at the breaker to all pool equipment Morning , everything was working fine with my Hayward pump. Hi Jeanette, somewhat normal with sand filters I would say first. Your salt level is between 2500-2600 parts per million (ppm). Hi when you say it shuts down, I assume you mean that the water stops flowing? Then check power (volts) coming into motor to verify and if it still wont come on (and makes no attempt to) its likely dead. If it continues, a new o-ring might be the ticket, yes. How Much Salt Belongs In Your Pool What do you have the output percentage set to? Hello, my motor runs for 20 seconds then stops. SOme pumps have an open bracket where you can see the shaft, but not Hayward. PDF | On Jan 1, 2009, Eduardo Keegan and others published Cognitive-behavior therapy. I filled the pool to the level line, but the air bubbles stayed. Any suggestions? Check in morning and basket is half full with water trickling in basket. If the wires are tight, I would suspect a bad capacitor, or wiring to or from the capacitor. When we turn on power, the pump does not make noise but the timer box and the circuit box make a light humming noise and then the circuit tripped. The issue is not a pump problem, not a filter problem, but a multiport valve problem. I just got my home back, I walked outside and pool level was well below jets. Pump is primed and water is coming out of the returns. Is there a thicker housing oring that could be installed to fix the leak? Have you checked the cells voltage, amperage, or done anything other troubleshooting? After running almost 24 hours the pressure went upto 30 which is the maxium number on our filter gauge and the water circulation stopped. A click on the outlet you say? If the salt cell is clean but the salt reading is off, the Aqua Rite will need to be recalibrated. Usually OK with a 12 lift, but more than that can be a struggle. Old pump ran on 120v and ran just fine till we broke it. I would say you are likely needing a new motor, and pump. What happens when you switch the output to super-chlorinate? Another possible cause is that the impeller is clogged with very small debris. If the blower prover switch does not close after the blower starts the control will stop the ignition trial go into lockout. When we first started both up there were no issues, however now when the heater kicks on the pump starts to make a high pitched noise. Also they winterized the place where the water circulates inside the pool and it wont unscrew so we can let some of the water out and put the original piece back on. Maybe not a pump issue, but supply issue. 1. You will have a choice of replacing the bearings or having a local electric motor shop do it, or replace the entire motor, or the entire pump. For Use With: Hayward AquaTrol Pool Chlorine Generator Brand: HAYWARD REVIEWS Q&A Powered by TurnTo Review More Purchases | My Posts There are no reviews for this item. Thanks. Good morning. Is this a new or older installation? It looks like no one has them in Stock and if I cant filter the pool, then it wont be usable. Could it have shut it self off from overheating? Hi and thanks for all this knowledge! It probably just needs to dry out, but breakers that trip do need to be fully turned to Off, before they can be turned back On again. Is this rare? We have Hayward Perflex filter parts here: https://www.intheswim.com/c/filter-parts?pcode=208&scode=SOCIBLOG. Not the 12VAC that it says should be there. Could the filter be plumbed backwards possibly? This code will display if 120V polarity is reversed, low voltage is detected, or if the ground path is not sufficient. You can patch the fitting usually with pool putty or silicone, but the best repair is to replace the fitting. Sean, Hi Sean, no worries. Davy: I have a Hayward super pump 1HP. Reinstalled Same problem recycled power. I backwash and rinse and start again but it does the same thing. GFCIs are sensitive, but for a reason. Everything just went downhill. BBC News - Dear This Week: your views on our show Turned it off and now it makes the grinding noise and turns off itself. The cap is located at 9 oclock in the rear of the motor, when they go bad, they sometimes bulge or crack, or turn brown or smell strongly of burnt wires They are cheap to replace, worth a shot, replace with identical MFD number. In a Quirked world where most people have a superpower-like uniqueness to them, His is among the most dangerous. "url": "https://intheswim.com/",
Valves were replaced with pipe and silicone applied to gaskets and O-rings during install and again yesterday while I was checking this list. Troubleshooting your Hayward salt system Piscines Trvi 8.88K subscribers Subscribe 57K views 3 years ago A salt water system control panel provides all sorts of information. Next, check continuity from lead to lead. We are trying to figure a way to start pumping the water put to clean the pool and get it going but we cant work the pump. Ob, and its just over 4 yrs old. In such case, filter pressure is lower than normal, if the impeller is clogged. It only blows air but when I take the lid off water comes out and the basket over flows. Also, using Teflon pool lube on the pump lid oring should help. It worked fine just prior to a filter cleaning. You have both filter pump and polaris pump on one timer? I presume Ill be looking at buying a new pump next year. Just replaced the sand and cleaned the fingers, replaced the o rings and have a psi of 15 and great suction. What do I need to do to fix this? Hello Dave, Any thoughts? "@context": "https://schema.org/",
I opened the back and was spinning the rod and it eventually started. Might be 2-years here is a chart on reading Hayward serial numbers, to find date of manufacture https://www.totallyhayward.com/techservices/attachments/Serial%20Number%20Read%20REVISED%201-2012.pdf, I have to reprime my hayward pump everytime I turn it on. When pumps dont run for a long time, they are susceptible to rust forming in between the stator and rotor. There is water under the motor not sure from where. Turned on the motor and smoke and a oil type substance came out of the capacitor. or if i let it rest for like 10 to 15 min it will start right up on its own when i hit the switch. The outlet the pump is plugged into, I suppose that is a 240V outlet. Just bought a new Hayward Perflex Series Extended Cycle Filtration Systems filter and cant get the motor to start. Hi, I have a H250PED2. I have called a repair company since the pump is under warranty and they told me that it is almost NEVER the pump and therefore if it is something else I will have to pay $89/hour for their serviceso I was hoping to exhaust all other possibilities before coughing up the moneyCan you recommend any tests that I can do? Most pump breakers are not GFI, it might not trip if it is a regular non-GFI. Step 3: Ensure that there isnt anything obstructing or blocking the flow. The pump keeps kicking off every 24 hours and I turn it back on by hitting filter. A longstanding legal battle over control of the old Apex Department Store properties in Pawtucket appears to be headed.. Apex Legal Funding is a lawsuit financing company that provides pre settlement funding and post settlement funding to plaintiffs. The main panel feeds a Tork timer, which I dont use the timer, I disconnected the timer motor. While you have the nest assy out of the tank, after hosing it off, soak it in a DE filter cleaner, to remove any scale and oils. HI Bernard, sounds like it could have cavitation, or a pipe diameter that is too small but pipe is the same. Before I purchase all new control board assembly, does this sound about right? hayward blue essence troubleshooting - Chhotisunehri.in Hi Jason, I would wait to spend the money, until certain that would be the fix. Hi Jodi, that could be two things either the pump impeller is severely clogged, keeping the motor shaft from turning or if the shaft spins freely, it is likely the capacitor (black cylinder in rear of motor) that has failed. well, possibly it just needs to dry out. It is good to let hayward know, because if they had a run of bad bearings, they will know about it, and want to know about it, and are more likely to help, if out of warranty. But, If you get no noise at all when you turn on the pump, no humming or grinding, or breaker tripping then check all the power connections, and check for power entering the motor, using a multimeter to test the terminals where the 2 wires connect. If needed, you could replace just the motor, and the shaft seal, and save a few hundred bucks. I have opened a pool and I have kept pump running 24 hrs due to Alge but few hours later there is no water moving in pool. Loose connections or insect infestation on contacts, or loose breaker etc, could also cause a different type of start/stop problem, very rapid. But first, remove the fingers again, and soak the entire Nest Assembly in a bucket filled with pool filter cleaner, to dissolve oils and scale. I replaced the capacitor last year. Hi Kelly, the first thing that comes to mind when you say pump stuck, is the common occurrence of rust building up between the rotor and stator, inside the motor. "width": "611",
The pump was working well since opening the pool in May, but the last few days it was quite weak. If the capacitor is bulged or cracked, or looks like it is burned or charred, you can assume that it is D.O.A. If youre correct that theres a problem with the internal bypass, what should I do? Checked circuit breakers inside and out and checked to make sure power is getting to pump. Hi Rudy, clicking on/off sounds like the switch in the rear of the motor, you may find either the centrifugal switch (dead center) or the stationary switch (6 oclock), may not be fully disengaging, or may be loose or bent. Step 2: Verify the accuracy of the salt readings (2700-3400 pm) with an independent test kit or by taking a water sample to your local pool store for testing. Is this rectifier bad? There are pegs all around that prevent moving the wrench beyond 11 and 12 oclock and because the shaft only has two flat sides we cannot get the wrench from another angle plus there are other pegs. Outlet works fine. Copyright 2022 In The Swim. If any of these readings are outside limits, replace motor. Only get big time cavitation and the basket empties about half. I have a max-flo vs pump and it cant seem to stay at a high rpm for any long stretch of time when its sunny. I closed the pool for winter. See below for more detail. I even plugged in the old pump and that too did not run? Posted: (10 days ago) Posted: (5 days ago) Mountainside Fitness is located at 9375 E Bell Rd, Scottsdale, AZ 85260.Mountainside Fitness can be contacted at (480) 502-2096. Likewise, check if the motor is wired correctly for the available field supply voltage. you can keep running it, while you get parts sure. How can I secure the top to the filter so the water will not pour out of it while the pump is on filter mode? *If your water temperature reads 215 degrees F, the cell temperature sensor is shorted and your cell needs replacing. "wordCount": "1009",
If the meter reads zero, and stays at zero the capacitor is bad. Corrosion inside the plug or socket. When you installed the new lateral assy, did the standpipe come all the way up to the top of the tank, and insert neatly into the bottom of the multiport valve? Since the flow seems correct, could it be blockage elsewhere? There could also be a short in the wiring to the pump, or from the breaker to the switch. }
. We just opened our pool up cleaned everything out put new D.E. I just had a power surge in my area and the heater has been turning on and wont turn off. 2 yrs is unusual for bearings to go. If you have a power meter you can turn clock on and see if power is getting to the motor 110-120V. gives you instant access to PDF files. Electrician was here at least 4 times and did not find anything. I see a break on the back side of control board where the wires plug into a 6 prong male connector. the 4th wire, the high speed wire. I did find the black power wire lose on the pump when checking the wire connections, so I reconnected it but to no avail. Hi Theresa, if the pump is overheating, and shutting off for 20 minutes to cool down and then starting again, thats not usually a good sign, altho could be incorrect voltage or loose connections. Second be sure that you are delivering 230V (+/- 10%) and that the motor is set to accept 230V (some are reversible to accept 115V too). The process, for changing a hayward pump seal is: 1. Problem is now the pool will not clean up (algae) and the pump is slow to prime. A pool guy who has since stopped operating put it in. Could also be a loose high speed wire from the switch. Should I shut down my system until I can get this fixed or is it safe for the motor to continue operation? This troubleshooting guide should give you all the tools and understanding you need to tackle any issue with your Hayward pool pump with confidence! Some times it has overheated, it did re start, but I want to make sure that the motor is supposed to run continuously. I have a maxi-flo 2 and it just stopped working. "author": {
Dont know how to fix this. If you want, you can remove the capacitor and wrap it in a heavy cloth, or rubber sheet just in case. Also check that water level is good in pool, and skimmer weir is not blocking water flow. To remedy this, simply open up your pump, and clean out any rubbish. Second thing could be loose wire connections, on the breaker, on the outlet, or on the cords connecting to the pump/trol, or damaged plug ends. Just opening pool. The correct replacement would be the AquaRite Main PCB (OEM) GLX-PCB-RITE. Profile, Create a Pool Professional Overheating pumps are usually DOA, in my experience, but there may be hope. Hayward Blue Essense-20 | Trouble Free Pool Third, check the back of the motor, the centrifugal switch on the end of the shaft and the stationary switch at 6 oclock to be sure they are tight and aligned tab to tab, and not loose or misaligned. what do you think the hum could be? Hi Joe, make sure that the pump shaft is spinning freely. I checked the breakers, plumbing, control panel, plumbingjust need to know if I shud prepare myself to buy a replacement. K-1766 Taylor Salt Test If you can, you can check voltage with a meter, on the breaker, to see how much voltage it is passing. Thanks Davy for your quick reply. Could vibration over time wear the pump housing? I turned power off from breaker, emptied basket, used fingers to check for debris in impellers, did not find any. They disappear when the pump is at a high speed. The post-purge cycle will be completed once the blower prover switch closes. But after that, you should be able to override any programs with the buttons. Both the pump motor and Polaris are wired out of the timer and the timer seems to be working correctly and I checked it by checking the voltage at the motor with the switch in the off position and then again with the switch in the on position. If not, keep reading. Any insight? the pop may have been the capacitor blowing, its a black cylinder located at 9 oclock in the rear of the motor. Hi, my Hayward pump is about 5 years old. https://www.facebook.com/inyopoolsFOLLOW us on TWITTER! We hope these charts help solve your Hayward pool heater problems. If you have a time clock or light switch in addition to the breaker, Id recommend using that to turn pump on/off, rather than the breaker. That could explain the pumping problems. Checked to see that there was no short in the wire with an ohms meter . Improper voltage wiring is the usual culprit for smoking pump motors. Good luck ~, Hi, I just replaced my 3/4 Hayward pump with a 1hp. Finally, in cases of very hard water, some of your sand bed may have calcified, and need to be replaced. I just dont know when it was purchased or how to even find out from the previous owners. Tim, all I can think of is maybe the pump is not self-priming pump? Right now I can hear the pump running hard when it is turned on, but pressure gauge shows 0. To spin the shaft, to find out of it spins freely, open up the rear of the pump motor, with power off, and use your fingers to spin the shaft. The pump has two drain plugs and the filter has one drain plug, all located on the bottom. If you are getting correct voltage into the rear of the motor (120V or 240V, +/- 10%), but still the motor makes no noise at all, its likely DOA the motor at least. The problem lies where the power dies [note to readers: motor cycling is not the same as pump cycling, where the water flow starts and stops, here I am talking about the motor itself starting/stopping], I have a Hayward sp2607x10 pump. Seal up the air leak in the front of the pump, then bleed off all the air in the filter tank, and the bubbling should cease. It is only a 2-3 year old pump. The leak and the surging you are experiencing, could be a result of the high filter pressure.
Bewitchment Demon Contract, Holly Monteleone Baby, Articles H
Valves were replaced with pipe and silicone applied to gaskets and O-rings during install and again yesterday while I was checking this list. Troubleshooting your Hayward salt system Piscines Trvi 8.88K subscribers Subscribe 57K views 3 years ago A salt water system control panel provides all sorts of information. Next, check continuity from lead to lead. We are trying to figure a way to start pumping the water put to clean the pool and get it going but we cant work the pump. Ob, and its just over 4 yrs old. In such case, filter pressure is lower than normal, if the impeller is clogged. It only blows air but when I take the lid off water comes out and the basket over flows. Also, using Teflon pool lube on the pump lid oring should help. It worked fine just prior to a filter cleaning. You have both filter pump and polaris pump on one timer? I presume Ill be looking at buying a new pump next year. Just replaced the sand and cleaned the fingers, replaced the o rings and have a psi of 15 and great suction. What do I need to do to fix this? Hello Dave, Any thoughts? "@context": "https://schema.org/",
I opened the back and was spinning the rod and it eventually started. Might be 2-years here is a chart on reading Hayward serial numbers, to find date of manufacture https://www.totallyhayward.com/techservices/attachments/Serial%20Number%20Read%20REVISED%201-2012.pdf, I have to reprime my hayward pump everytime I turn it on. When pumps dont run for a long time, they are susceptible to rust forming in between the stator and rotor. There is water under the motor not sure from where. Turned on the motor and smoke and a oil type substance came out of the capacitor. or if i let it rest for like 10 to 15 min it will start right up on its own when i hit the switch. The outlet the pump is plugged into, I suppose that is a 240V outlet. Just bought a new Hayward Perflex Series Extended Cycle Filtration Systems filter and cant get the motor to start. Hi, I have a H250PED2. I have called a repair company since the pump is under warranty and they told me that it is almost NEVER the pump and therefore if it is something else I will have to pay $89/hour for their serviceso I was hoping to exhaust all other possibilities before coughing up the moneyCan you recommend any tests that I can do? Most pump breakers are not GFI, it might not trip if it is a regular non-GFI. Step 3: Ensure that there isnt anything obstructing or blocking the flow. The pump keeps kicking off every 24 hours and I turn it back on by hitting filter. A longstanding legal battle over control of the old Apex Department Store properties in Pawtucket appears to be headed.. Apex Legal Funding is a lawsuit financing company that provides pre settlement funding and post settlement funding to plaintiffs. The main panel feeds a Tork timer, which I dont use the timer, I disconnected the timer motor. While you have the nest assy out of the tank, after hosing it off, soak it in a DE filter cleaner, to remove any scale and oils. HI Bernard, sounds like it could have cavitation, or a pipe diameter that is too small but pipe is the same. Before I purchase all new control board assembly, does this sound about right? hayward blue essence troubleshooting - Chhotisunehri.in Hi Jason, I would wait to spend the money, until certain that would be the fix. Hi Jodi, that could be two things either the pump impeller is severely clogged, keeping the motor shaft from turning or if the shaft spins freely, it is likely the capacitor (black cylinder in rear of motor) that has failed. well, possibly it just needs to dry out. It is good to let hayward know, because if they had a run of bad bearings, they will know about it, and want to know about it, and are more likely to help, if out of warranty. But, If you get no noise at all when you turn on the pump, no humming or grinding, or breaker tripping then check all the power connections, and check for power entering the motor, using a multimeter to test the terminals where the 2 wires connect. If needed, you could replace just the motor, and the shaft seal, and save a few hundred bucks. I have opened a pool and I have kept pump running 24 hrs due to Alge but few hours later there is no water moving in pool. Loose connections or insect infestation on contacts, or loose breaker etc, could also cause a different type of start/stop problem, very rapid. But first, remove the fingers again, and soak the entire Nest Assembly in a bucket filled with pool filter cleaner, to dissolve oils and scale. I replaced the capacitor last year. Hi Kelly, the first thing that comes to mind when you say pump stuck, is the common occurrence of rust building up between the rotor and stator, inside the motor. "width": "611",
The pump was working well since opening the pool in May, but the last few days it was quite weak. If the capacitor is bulged or cracked, or looks like it is burned or charred, you can assume that it is D.O.A. If youre correct that theres a problem with the internal bypass, what should I do? Checked circuit breakers inside and out and checked to make sure power is getting to pump. Hi Rudy, clicking on/off sounds like the switch in the rear of the motor, you may find either the centrifugal switch (dead center) or the stationary switch (6 oclock), may not be fully disengaging, or may be loose or bent. Step 2: Verify the accuracy of the salt readings (2700-3400 pm) with an independent test kit or by taking a water sample to your local pool store for testing. Is this rectifier bad? There are pegs all around that prevent moving the wrench beyond 11 and 12 oclock and because the shaft only has two flat sides we cannot get the wrench from another angle plus there are other pegs. Outlet works fine. Copyright 2022 In The Swim. If any of these readings are outside limits, replace motor. Only get big time cavitation and the basket empties about half. I have a max-flo vs pump and it cant seem to stay at a high rpm for any long stretch of time when its sunny. I closed the pool for winter. See below for more detail. I even plugged in the old pump and that too did not run? Posted: (10 days ago) Posted: (5 days ago) Mountainside Fitness is located at 9375 E Bell Rd, Scottsdale, AZ 85260.Mountainside Fitness can be contacted at (480) 502-2096. Likewise, check if the motor is wired correctly for the available field supply voltage. you can keep running it, while you get parts sure. How can I secure the top to the filter so the water will not pour out of it while the pump is on filter mode? *If your water temperature reads 215 degrees F, the cell temperature sensor is shorted and your cell needs replacing. "wordCount": "1009",
If the meter reads zero, and stays at zero the capacitor is bad. Corrosion inside the plug or socket. When you installed the new lateral assy, did the standpipe come all the way up to the top of the tank, and insert neatly into the bottom of the multiport valve? Since the flow seems correct, could it be blockage elsewhere? There could also be a short in the wiring to the pump, or from the breaker to the switch. }
. We just opened our pool up cleaned everything out put new D.E. I just had a power surge in my area and the heater has been turning on and wont turn off. 2 yrs is unusual for bearings to go. If you have a power meter you can turn clock on and see if power is getting to the motor 110-120V. gives you instant access to PDF files. Electrician was here at least 4 times and did not find anything. I see a break on the back side of control board where the wires plug into a 6 prong male connector. the 4th wire, the high speed wire. I did find the black power wire lose on the pump when checking the wire connections, so I reconnected it but to no avail. Hi Theresa, if the pump is overheating, and shutting off for 20 minutes to cool down and then starting again, thats not usually a good sign, altho could be incorrect voltage or loose connections. Second be sure that you are delivering 230V (+/- 10%) and that the motor is set to accept 230V (some are reversible to accept 115V too). The process, for changing a hayward pump seal is: 1. Problem is now the pool will not clean up (algae) and the pump is slow to prime. A pool guy who has since stopped operating put it in. Could also be a loose high speed wire from the switch. Should I shut down my system until I can get this fixed or is it safe for the motor to continue operation? This troubleshooting guide should give you all the tools and understanding you need to tackle any issue with your Hayward pool pump with confidence! Some times it has overheated, it did re start, but I want to make sure that the motor is supposed to run continuously. I have a maxi-flo 2 and it just stopped working. "author": {
Dont know how to fix this. If you want, you can remove the capacitor and wrap it in a heavy cloth, or rubber sheet just in case. Also check that water level is good in pool, and skimmer weir is not blocking water flow. To remedy this, simply open up your pump, and clean out any rubbish. Second thing could be loose wire connections, on the breaker, on the outlet, or on the cords connecting to the pump/trol, or damaged plug ends. Just opening pool. The correct replacement would be the AquaRite Main PCB (OEM) GLX-PCB-RITE. Profile, Create a Pool Professional Overheating pumps are usually DOA, in my experience, but there may be hope. Hayward Blue Essense-20 | Trouble Free Pool Third, check the back of the motor, the centrifugal switch on the end of the shaft and the stationary switch at 6 oclock to be sure they are tight and aligned tab to tab, and not loose or misaligned. what do you think the hum could be? Hi Joe, make sure that the pump shaft is spinning freely. I checked the breakers, plumbing, control panel, plumbingjust need to know if I shud prepare myself to buy a replacement. K-1766 Taylor Salt Test If you can, you can check voltage with a meter, on the breaker, to see how much voltage it is passing. Thanks Davy for your quick reply. Could vibration over time wear the pump housing? I turned power off from breaker, emptied basket, used fingers to check for debris in impellers, did not find any. They disappear when the pump is at a high speed. The post-purge cycle will be completed once the blower prover switch closes. But after that, you should be able to override any programs with the buttons. Both the pump motor and Polaris are wired out of the timer and the timer seems to be working correctly and I checked it by checking the voltage at the motor with the switch in the off position and then again with the switch in the on position. If not, keep reading. Any insight? the pop may have been the capacitor blowing, its a black cylinder located at 9 oclock in the rear of the motor. Hi, my Hayward pump is about 5 years old. https://www.facebook.com/inyopoolsFOLLOW us on TWITTER! We hope these charts help solve your Hayward pool heater problems. If you have a time clock or light switch in addition to the breaker, Id recommend using that to turn pump on/off, rather than the breaker. That could explain the pumping problems. Checked to see that there was no short in the wire with an ohms meter . Improper voltage wiring is the usual culprit for smoking pump motors. Good luck ~, Hi, I just replaced my 3/4 Hayward pump with a 1hp. Finally, in cases of very hard water, some of your sand bed may have calcified, and need to be replaced. I just dont know when it was purchased or how to even find out from the previous owners. Tim, all I can think of is maybe the pump is not self-priming pump? Right now I can hear the pump running hard when it is turned on, but pressure gauge shows 0. To spin the shaft, to find out of it spins freely, open up the rear of the pump motor, with power off, and use your fingers to spin the shaft. The pump has two drain plugs and the filter has one drain plug, all located on the bottom. If you are getting correct voltage into the rear of the motor (120V or 240V, +/- 10%), but still the motor makes no noise at all, its likely DOA the motor at least. The problem lies where the power dies [note to readers: motor cycling is not the same as pump cycling, where the water flow starts and stops, here I am talking about the motor itself starting/stopping], I have a Hayward sp2607x10 pump. Seal up the air leak in the front of the pump, then bleed off all the air in the filter tank, and the bubbling should cease. It is only a 2-3 year old pump. The leak and the surging you are experiencing, could be a result of the high filter pressure.
Bewitchment Demon Contract, Holly Monteleone Baby, Articles H